{"id":732,"date":"2026-11-12T03:28:03","date_gmt":"2026-11-11T19:28:03","guid":{"rendered":"http:\/\/www.aptoinn.com\/blog\/?p=732"},"modified":"2026-11-12T03:28:03","modified_gmt":"2026-11-11T19:28:03","slug":"do-shimadzu-gear-pumps-require-regular-lubrication-4644-3c3c08","status":"publish","type":"post","link":"http:\/\/www.aptoinn.com\/blog\/2026\/11\/12\/do-shimadzu-gear-pumps-require-regular-lubrication-4644-3c3c08\/","title":{"rendered":"Do SHIMADZU gear pumps require regular lubrication?"},"content":{"rendered":"<p>If you\u2019ve ever worked in analytical instrumentation, process engineering, or fluid handling, chances are you\u2019ve encountered SHIMADZU Series Gear Pumps. As a trusted supplier of these precision pumps, I get dozens of questions every week\u2014none more consistent than, \u201cDo these pumps need regular lubrication?\u201d It\u2019s a fair question: improper maintenance is one of the top reasons gear pumps fail prematurely, and there\u2019s a lot of misinformation online about how to care for high-performance units like SHIMADZU\u2019s. Let\u2019s break this down with real, hands-on experience, because when it comes to these pumps, the answer isn\u2019t a simple \u201cyes\u201d or \u201cno\u201d\u2014it\u2019s rooted in their design, application, and how you operate them. <a href=\"https:\/\/www.bailehydraulic.com\/hydraulic-gear-pump\/shimadzu-series-gear-pump\/\">SHIMADZU Series Gear Pump<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.bailehydraulic.com\/uploads\/37869\/small\/rexroth-sl30ga1-4x-check-valvead76a.jpg\"><\/p>\n<p>First, let\u2019s start with why lubrication matters for gear pumps in general. Gear pumps work by meshing two interlocking gears inside a sealed casing. As those gears rotate, they create a low-pressure zone on the intake side that draws fluid in, then trap and carry that fluid around the casing\u2019s inner walls, and finally push it out under pressure on the discharge side. For the gears to mesh smoothly and the pump\u2019s internal components (like the shaft bearings, the casings, and the gear teeth) to avoid metal-on-metal contact, a thin layer of lubricant between moving parts is non-negotiable. Without it, friction builds up fast, leading to excessive wear, reduced flow rates, and even catastrophic pump failure.<\/p>\n<p>Now, that\u2019s the generic rule, but SHIMADZU\u2019s Series Gear Pumps aren\u2019t generic. Their design is engineered for two primary categories of use: self-lubricating and non-lubricating, depending on the model and the fluid they\u2019re handling. Let\u2019s dive into the differences here, because that\u2019s where most buyers get confused.<\/p>\n<p>The self-lubricating models\u2014think of our SPG-20 and SPG-30 series, which are common in HPLC systems and high-purity analytical fluid handling\u2014are built to run on the process fluid itself. That\u2019s not a marketing gimmick; it\u2019s a deliberate design choice. The gear teeth, bearings, and casings are machined from materials like ceramic or coated stainless steel that have low friction coefficients when in contact with compatible liquids, and the tight tolerances in the casing mean a thin film of the process fluid gets trapped between moving parts as the gears rotate. For these models, you don\u2019t need to add external lubrication\u2014because the fluid you\u2019re pumping is the lubricant. But here\u2019s the catch: this only works if the process fluid is lubricious. If you\u2019re pumping a very low-viscosity fluid (like pure water at 25\u00b0C, which has a viscosity of just 1 mPa\u00b7s) or a dry gas, that thin film breaks down. Run a self-lubricating pump with a non-lubricious, low-viscosity fluid for more than a few hours without intervention, and you\u2019ll see accelerated gear wear.<\/p>\n<p>Then there are the non-lubricating models, like our SPG-50 and SPG-100 series, which are used in industrial process applications\u2014think transferring oils, solvents, or other industrial fluids. These models have plain bearings and gears that require external lubrication to operate correctly. SHIMADZU specifies a regular lubrication schedule for these, and it\u2019s not arbitrary. Let me share a real example from a customer I worked with last year: a food and beverage plant that was using an SPG-50 pump to transfer edible oil from storage tanks to processing lines. At first, they skipped the scheduled lubrication, thinking \u201cit\u2019s just oil, it\u2019ll lubricate itself.\u201d Within six months, the pump\u2019s discharge pressure had dropped by 20%\u2014so much that they had to slow down their entire production line to keep up. When they pulled the pump apart, the gear bearings were scored, and the gear teeth had excessive pitting. The issue? The edible oil they were pumping was refined to remove impurities, which reduced its lubricity to levels too low to properly lubricate the pump\u2019s internal metal components. Once they followed our recommended lubrication schedule (using a food-grade grease that SHIMADZU approves, applied every 1,000 hours of operation), their pump ran for another 18 months without issues.<\/p>\n<p>That\u2019s a key point: even when a pump is designed to run on process fluid, the fluid\u2019s quality matters more than you think. A lot of customers assume that any fluid with \u201coil\u201d in the name is lubricious, but that\u2019s not true. For example, synthetic hydraulic fluids have better lubricity than many refined edible oils, and high-purity solvents like ethanol or hexane have almost none. If you\u2019re operating a SHIMADZU Series Gear Pump in an application where the process fluid\u2019s lubricity is below 50 mPa\u00b7s (a rough benchmark for adequate self-lubrication), you\u2019ll need to supplement with external lubrication.<\/p>\n<p>Now, let\u2019s talk about the maintenance schedule SHIMADZU recommends, because that\u2019s where I see most customers deviating from best practices. For self-lubricating models, the rule is: inspect the pump every 500 hours of operation, and check the gear teeth and bearings for signs of wear. If you notice scoring, pitting, or a drop in flow rate of more than 5%, you\u2019ll need to add a small amount of compatible lubricant to the intake line to keep the film intact. For non-lubricating models, the schedule is more strict: grease the bearings every 800 hours, and replace the internal lubricant seal every 2,000 hours. It\u2019s tempting to stretch these intervals, but even a 20% extension can cut the pump\u2019s lifespan in half.<\/p>\n<p>I also want to address a common myth I hear from new customers: \u201cSHIMADZU pumps are high-quality, so they don\u2019t need regular maintenance.\u201d This is partially true\u2014their pumps are built with precision materials, and many have features like anti-friction coatings or sealed bearings that reduce wear. But \u201clow wear\u201d doesn\u2019t mean \u201cno wear.\u201d Even the best pumps will have friction, and without lubrication, that friction turns into heat and damage. I\u2019ve seen customers try to skip lubrication on a brand-new SHIMADZU SPG-30 pump, and it failed in 120 hours\u2014all because the process fluid they were pumping was deionized water, which has almost no lubricity. The gears ground together, and the pump seized up entirely. That\u2019s an avoidable mistake, and it\u2019s one I spend a lot of time educating customers on.<\/p>\n<p>Another factor that affects lubrication needs: operating pressure and temperature. If you\u2019re running a SHIMADZU Series Gear Pump at above its rated pressure (most standard models max out at 10 bar, with high-pressure versions going up to 25 bar), the internal clearances between gears and casings get tighter. This means the lubricant film has to be thicker to prevent metal-on-metal contact, so you\u2019ll need to ensure the lubrication supply is consistent. Similarly, if you\u2019re operating at high temperatures (above 60\u00b0C for most models), the lubricant breaks down faster, so you\u2019ll need to shorten your lubrication intervals. A pump running at 80\u00b0C will need grease applied every 500 hours, not 800, to maintain proper protection.<\/p>\n<p>So, putting this all together: Do SHIMADZU Series Gear Pumps require regular lubrication? The short answer is, it depends on the model and your application. If you\u2019re using a self-lubricating model with a lubricious process fluid (viscosity \u226550 mPa\u00b7s, no harsh solvents or pure water), you don\u2019t need external lubrication, but you do need regular inspections. If you\u2019re using a non-lubricating model, or if your process fluid has low lubricity, you absolutely need a scheduled lubrication routine following SHIMADZU\u2019s specifications. Skipping that routine is the number one cause of premature pump failure, and it\u2019s the easiest mistake to avoid.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.bailehydraulic.com\/uploads\/37869\/small\/daikin-ls-g02-2ca-30-en-ls-series-low-watt82d8f.jpg\"><\/p>\n<p>As a supplier of SHIMADZU Series Gear Pumps, I don\u2019t just sell pumps\u2014I help customers keep them running for years. If you\u2019re not sure which model is right for your application, or if you have questions about lubrication schedules, wear inspection, or replacement parts, don\u2019t hesitate to reach out. We can walk through your operating conditions, share real-world examples of similar applications, and help you build a maintenance plan that works for your business. Whether you\u2019re troubleshooting a pump that\u2019s underperforming, or looking to purchase a new SHIMADZU Series Gear Pump, we\u2019re here to provide the support you need.<\/p>\n<p><a href=\"https:\/\/www.bailehydraulic.com\/other-accessories\/accumulator\/\">Accumulator<\/a> References<\/p>\n<ol>\n<li>SHIMADZU Corporation. &quot;SPG Series Gear Pump Operation &amp; Maintenance Manual&quot;. 2022.<\/li>\n<li>American Gear Manufacturers Association (AGMA). &quot;Lubrication Guidelines for Rotary Gear Pumps&quot;. AGMA Standard 6011-A19, 2019.<\/li>\n<li>Mott, R.L. &quot;Hydraulics and Fluid Mechanics&quot;. 7th ed., Pearson, 2021.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.bailehydraulic.com\/\">Shijiazhuang Baile Electromechanical Equipment Co., Ltd.<\/a><br \/>Shijiazhuang Baile Electromechanical Equipment Co., Ltd. is well-known as one of the leading shimadzu series gear pump manufacturers and suppliers in China. If you&#8217;re going to buy high quality shimadzu series gear pump at competitive price, welcome to get more information from our factory.<br \/>Address: Torch Industrial Zone, Licheng District, Quanzhou City, Fujian Province<br \/>E-mail: sales02@bailehydraulic.com<br \/>WebSite: <a href=\"https:\/\/www.bailehydraulic.com\/\">https:\/\/www.bailehydraulic.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever worked in analytical instrumentation, process engineering, or fluid handling, chances are you\u2019ve encountered &hellip; <a title=\"Do SHIMADZU gear pumps require regular lubrication?\" class=\"hm-read-more\" href=\"http:\/\/www.aptoinn.com\/blog\/2026\/11\/12\/do-shimadzu-gear-pumps-require-regular-lubrication-4644-3c3c08\/\"><span class=\"screen-reader-text\">Do SHIMADZU gear pumps require regular lubrication?<\/span>Read more<\/a><\/p>\n","protected":false},"author":395,"featured_media":732,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[695],"class_list":["post-732","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-shimadzu-series-gear-pump-422a-3ce5c8"],"_links":{"self":[{"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/posts\/732","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/users\/395"}],"replies":[{"embeddable":true,"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/comments?post=732"}],"version-history":[{"count":0,"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/posts\/732\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/posts\/732"}],"wp:attachment":[{"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/media?parent=732"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/categories?post=732"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.aptoinn.com\/blog\/wp-json\/wp\/v2\/tags?post=732"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}